0xe1000076 The internal buffer that holds this mechanism’s properties is too small.
Explanation: This is an internal TDGSS error.
Generated By: TDGSS Package.
For Whom: System Support Representative.
Remedy: Contact the Global Support Center.
0xe1000077 Could not duplicate buffer as requested
Explanation: The buffer could not be duplicated as requested because either the source or destination buffer (but not
both) was NULL.
Generated By: TDGSS Package.
For Whom: System Support Representative.
Notes: See major status for further information.
Remedy: Contact the Global Support Center.
0xe1000078 Could not repackage buffer as requested
Explanation: A valid security mechanism is required to repackage the buffer, but was not supplied.
Generated By: TDGSS Package.
For Whom: System Support Representative.
Notes: See major status for further information.
Remedy: Contact the Global Support Center.
0xe1000079 Could not duplicate OidSet as requested
Explanation: The OidSet could not be duplicated because no OidSet destination was specified.
Generated By: TDGSS Package.
For Whom: System Support Representative.
Notes: See major status for further information.
Remedy: Contact the Global Support Center.
0xe100007a Could not repackage OidSet as requested
Explanation: A valid security mechanism is required to repackage the OidSet, but was not supplied.
Generated By: TDGSS Package.
For Whom: System Support Representative.
Notes: See major status for further information.
Remedy: Contact the Global Support Center.
0xe100007b Could not obtain mechanism oid as requested
Explanation: The mechanism specified could not be found.
Generated By: TDGSS Package.
For Whom: System Support Representative.
Notes: See major status for further information.
Remedy: Contact the Global Support Center.
0xe100007c Could not obtain mechanism string as requested
Explanation: The mechanism string could not be obtained. This can be due to either an invalid mechanism being
selected or if there is no place to write the results. The major status will indicate which reason.
Generated By: TDGSS Package.
For Whom: System Support Representative.
Notes: See major status for further information.
Remedy: Contact the Global Support Center.
0xe100007d Could not get algorithm QOP as requested
Explanation: The Algorithm QOP could not be obtained. This can be due to either an invalid mechanism being selected
or if there is no place to write the results. The major status will indicate which reason.
Generated By: TDGSS Package.
For Whom: System Support Representative.
Notes: See major status for further information.
Remedy: Contact the Global Support Center.
0xe100007e The OID string supplied was too small
Explanation: According to the X.208 specification, an OID string must consist of a minimum of two numbers, separated
by an ASCII “.” This means that the absolute minimum OID string size is 3 (for example “1.2”).
Generated By: TDGSS Package.
For Whom: System Support Representative.
Remedy: Contact the Global Support Center.
0xe100007f Was not able to obtain the DER form of the OID
Explanation: An error has occured in gssp_oidstr_to_oidder.
Generated By: TDGSS Package.
For Whom: System Support Representative.
Notes: See major status for further information.
Remedy: Contact the Global Support Center.
Above are list of Teradata Errors or Failure Codes from Error 0xe1000076 To 0xe100007f received while performing certain operation against Teradata Database or related products.
What are Teradata Database Errors?
In general, each Teradata error message contains the following information:
• The message number.
• The message text. This text is usually returned with the message number. Some messages employ word substitution, where the word substituted represents the system-replacement of a term more specific to the occurrence.
• An explanation of how the error may have occurred.
• Generated-by text that indicates the software module which initiated the message. This field serves a diagnostic purpose for support and development personnel.
• A remedy which suggests how to resolve the condition.
Hope this was helpful.
Thanks,
SQLServerF1 Team
Information about Teradata SQL Error and Failure Codes and Error Messages on Windows, Linux Operating Systems.